WPE DIESEL GENERATORS
PREPARATION BEFORE START
4
Charging the battery
Battery electrolyte contains sulphuric acid. Protect
your eyes, skin and clothing. In case of contact, flush
thoroughly with water and get prompt attention,
especially if your eyes are affected.
Batteries generate hydrogen gas, which can flames or
sparks near a battery, especially during charging.
Charge the battery in a fully ventilated area.
WARNING
Know how to stop the generator quickly, and
understand how to operate all of the controls. Never
permit anyone to operate the generator without
proper instruction.
Always wear a helmet, safety shoes and proper
clothing. Keep pets and children away from the
generator when it is in operation.
PREPARATION BEFORE START
Selection and handling of fuel
Only light diesel fuel can be used.
The fuel must be filtered .
Fuel should be free of water or dust because these
can contaminate the fuel injection system.
Do not overfill the tank beyond the top of the red plug
inside the fuel tank filter, use fuel gauge on top of tank.
Do not smoke and allow sparks in the area where the
engine is refueled or where gasoline is stored.
Do not spill fuel when refueling, make sure the filter
cap is securely closed.
Selection and handling of oil
Set the generator on a level surface.
Fill the engine oil into the inlet.
To check the oil level, simply dip the dipstick into the
pan. Do not screw in the dipstick when checking.
NOTICE
Nothing effects the performance and durability of
the generator more than the oil you use. If inferior oil
is used or if your engine oil is not changed regularly,
the risk of piston seizure, piston ring sticking and
accelerated wear of the cylinder liner, bearings and
other moving components increase significantly.
Make sure to check the oil level and to refill with oil to
the specified level before starting the generator, even
though it is equipped with a low oil pressure warning
system.
If your generator doesn’t start by the 5th attempted or
starts and cuts out, your oil level is to low and needs to
topped up.
NOTICE
Oil should be changed after the first 10 hours (or 1
month) of use and then every 3 months or 100 hours
of use.
Always drain the oil while the engine is warm but
not hot . It is difficult to drain the oil completely after
cooling.
As a general rule oil is full when it can be visually
seen on the middle - upper threads of the port. Do not
over fill otherwise this will result in degraded engine
performance and possible damage to engine.
WARNING
NEVER add or attempt to change oil into the
generator while the engine is running.
Check air filter
Loosen the wing nut, detach the cover of air cleaner
and remove the element. Do not wash air cleaner
element with detergent . Use water or petrol (MUST
allow to dry before replacing).
The air cleaner element must be changed when the
output of engine decreases or the color of exhaust is
abnormal.
Never run the generator without the air cleaner
element. This may cause rapid engine wear.
Reattach the cover of air cleaner and tighten the wing
nut.
Ensure no load on generator
Turn off the main circuit breaker and any other loads.
Be sure to turn off the main circuit breaker before
starting the generator. If the switch is not on the “OFF“
Pobierz instrukcję w języku polskim (PDF, 2.33 MB)
(Apelujemy o dbanie o środowisko i drukowanie instrukcji tylko wtedy, gdy jest to niezbędne)

Loading…

Ocena

Podziel się z nami swoją opinią na temat Warrior 6500SVWRC-(EU) Generator i oceń urządzenie. Chcesz podzielić się swoimi doświadczeniami z tym produktem lub zadać pytanie? Zostaw komentarz na dole strony.
Czy jesteś zadowolony z Warrior 6500SVWRC-(EU) Generator?
Tak Nie
Zostań pierwszą osobą, która oceni ten produkt
0 głosów

Dołącz do dyskusji na temat tego produktu

Tutaj możesz podzielić się swoją opinią na temat Warrior 6500SVWRC-(EU) Generator. Jeśli masz pytanie, najpierw dokładnie przeczytaj instrukcję. Zapytanie o instrukcję można złożyć za pomocą naszego formularza kontaktowego.

Więcej o tej instrukcji

Rozumiemy, że miło jest mieć papierową instrukcję obsługi Warrior 6500SVWRC-(EU) Generator. Zawsze możesz pobrać instrukcję z naszej strony internetowej i wydrukować ją samodzielnie. Jeśli chcesz otrzymać oryginalną instrukcję, zalecamy skontaktowanie się z Warrior. Być może będą w stanie dostarczyć oryginalną instrukcję. Szukasz instrukcji swojego Warrior 6500SVWRC-(EU) Generator w innym języku? Wybierz preferowany język na naszej stronie głównej i wyszukaj numer modelu, aby sprawdzić, czy jest on dostępny.

Dane techniczne

Marka Warrior
Model 6500SVWRC-(EU)
Kategoria Generatory
Typ pliku PDF
Rozmiar pliku 2.33 MB

Wszystkie podręczniki dla Warrior Generatory
Więcej podręczników Generatory

Instrukcja Warrior 6500SVWRC-(EU) Generator

Produkty powiązane

Powiązane kategorie