Instrukcja Steinel IS 140-2 Czujnik ruchu

Potrzebujesz instrukcji dla swojego Steinel IS 140-2 Czujnik ruchu? Poniżej możesz bezpłatnie obejrzeć i pobrać instrukcję w formacie PDF w języku polskim. Ten produkt ma obecnie zadane 0 pytania, 5 komentarzy i ma 11 głosów przy średniej ocenie produktu wynoszącej 18/100. Jeśli nie jest to podręcznik, którego szukasz, skontaktuj się z nami.

Czy Twój produkt nie działa, a w instrukcji obsługi brakuje rozwiązania Twojego problemu? Udaj się do Repair Café, gdzie naprawisz swój sprzęt za darmo.

Instrukcja

Loading…

Principle
Movement triggers lights, alarms and many other devices - for your convenience and safety. The integrated
pyroelectric infrared detector senses the invisible heat radiated from moving objects (people, animals, etc.).
The heat detected in this way is converted electronically into a signal that activates the load connected. Heat
radiation is not detected through obstacles, such as walls or glass, and will therefore not activate the light.
Safety warnings
During installation, the electrical wiring being connected must be dead. Therefore, switch off the power first
and use a voltage tester to check that the power supply is disconnected.
Installing this unit involves work on the mains voltage supply. This must therefore be carried out
in accordance with applicable national wiring regulations and electrical operating conditions.
(
D
- VDE 0100,
A
-ÖVE-ÖNORM E8001-1,
-SEV 1000)
Only use genuine replacement parts.
Do not dismantle the unit yourself. It must only be repaired by a specialist workshop.
Installation
L = live conductor (usually black or brown)
Connection with concealed wiring
N = neutral conductor (usually blue)
Connection with exposed wiring
PE = any protective earth conductor (green/yellow)
Attention: Loop the protective-earth conductor through if necessary. A mains power switch for turning the unit
ON and OFF may of course be installed in the mains supply lead. Important: Reversing the connections may
result in damage to the unit. Please note that the circuit must be protected by a 10 A circuit breaker.
Optimum mounting height: 2 m for wall mounting
Function
Twilight setting (factory setting: daylight operation at 2000 lux):
The sensor's response threshold can be infinitely varied from 2 – 2000 lux.
Control dial set to = daylight operation at approx. 2000 lux.
Control dial set to = night-time operation at approx. 2 lux.
To adjust the detection zone in daylight, the control dial must be set to (daylight operation).
Time setting (factory setting: 8 sec.): Light 'ON' time can be set from 8 secs. to 35 mins.
Control dial set to – = shortest time (8 sec.)
Control dial set to + = longest time (35 min.)
When setting the detection zone, we recommend selecting the shortest time.
Adjust detection zone at swivel mount
Reach can be adjusted to between 2 and 14 m by tilting the lens through 90°.
Swivelling for align-
ment on the wall.
Reach 1 – 14 m. Max. setting permits detection along the building wall
.
Using
adhesive shrouds, e.g. to mask out paths or neighbouring property. Important: The most reliable way of detect-
ing movement is to install the sensor so that it points across the direction in which a person would walk and by
ensuring that no obstacles (such as trees, walls etc.) obstruct the line of vision. Reach is restricted when you
walk straight towards the sensor.
Troubleshooting (Fault / Cause
Remedy
)
No power / Fuse faulty, not switched on
new fuse, turn power switch ON, check lead with voltage tester.
Will not switch ON / Surroundings still too bright
wait until response threshold is reached or adjust setting
/
Bulb faulty
change bulb /
Power switch OFF
switch on /
Detection zone not properly targeted
readjust.
Will not switch OFF / Permanent movement in the detection zone
adjust detection zone
. Keeps switching
ON/OFF / There is a light in the detection zone
change detection zone, increase distance
. Switches ON
when unwanted / Detecting cars on the road, for example
change detection zone, tilt sensor down.
Reach changing / Differing ambient temperatures
at low temperatures, shorten reach by tilting sensor
down; at high temperatures, tilt sensor up.
Declaration of conformity
This product complies with Low Voltage Directive 2006/95/EC, EMC Directive 2004/108/EC and RoHS Directive
2002/95/EC.
Functional warranty
This STEINEL product has been manufactured with great care, tested for proper operation and safety in accordance
with applicable regulations and then subjected to random sample inspection. STEINEL guarantees that it is perfect
condition and proper working order. The warranty period is 36 months, starting from the date of sale to the con-
sumer. We will remedy defects caused by material flaws or manufacturing faults. The warranty will be met by
repair or replacement of defective parts at our own discretion. The warranty does not cover damage to wear parts,
nor does it cover damage or defects caused by improper treatment, maintenance or the use on non-genuine parts.
Further consequential damage to other objects shall be excluded. The warranty will only be honoured if the product
is sent to the appropriate Service Centre fully assembled and well packed with a brief description of the fault,
receipt or invoice (date of purchase and dealer's stamp).
Service:
Our Customer Service Department will repair faults not covered by warranty or after the warranty period. Please
send the product well packed to your nearest Service Centre.
ENGLISH
GB
18
13
7
8
79
10
11
12
710
11a
IS 140-2
i
109599501 02/2012_C
Pobierz instrukcję w języku polskim (PDF, 18.03 MB)
(Apelujemy o dbanie o środowisko i drukowanie instrukcji tylko wtedy, gdy jest to niezbędne)

Loading…

Ocena

Podziel się z nami swoją opinią na temat Steinel IS 140-2 Czujnik ruchu i oceń urządzenie. Chcesz podzielić się swoimi doświadczeniami z tym produktem lub zadać pytanie? Zostaw komentarz na dole strony.
Czy jesteś zadowolony z Steinel IS 140-2 Czujnik ruchu?
Tak Nie
18%
82%
11 głosów

Dołącz do dyskusji na temat tego produktu

Tutaj możesz podzielić się swoją opinią na temat Steinel IS 140-2 Czujnik ruchu. Jeśli masz pytanie, najpierw dokładnie przeczytaj instrukcję. Zapytanie o instrukcję można złożyć za pomocą naszego formularza kontaktowego.

JEAN LION 11-03-2021
WITAM MAM PROSTOKĄTNY MODEL ZE STALI NIERDZEWNEJ Z KULKĄ PONIŻEJ, KTÓRY SŁUŻY JAKO CZUJNIK NIE ROZUMIEJ, JAK FUNKCJE SĄ AKTYWOWANE TO JEST MODEL ZE SŁOŃCEM, KSIĘŻYCEM I ZEGAREM TO PRZYCISKI, NA KTÓRE MUSISZ NACIŚNIĘĆ MOŻESZ WYJAŚNIĆ DLA MNIE BĘDZIE TO, ŻE ZOSTAJE WŁĄCZONE NA 5MN W NOCY DZIĘKI GDY NACIŚNIĘ PRZYCISKI ZAPALA SIĘ CZERWONA LAMPKA I PRÓBUJĘ REGULOWAĆ JUŻ NIE WYŁĄCZA SIĘ

odpowiedz | To było pomocne (10) (Przetłumaczone przez Google)
Leroy Jean Luc 19-12-2020
Witam, kupuję czujnik ruchu Steinel, fioletowy przewód zaciska się do czego

odpowiedz | To było pomocne (8) (Przetłumaczone przez Google)
erik klerkx 07-01-2022
Czy muszę wywiercić otwór 5mm w czujniku?

odpowiedz | To było pomocne (6) (Przetłumaczone przez Google)
Dieter Gibbösch 31-08-2019
Czy czujka ruchu Steinel iS 140-2 nadaje się również do montażu na suficie na zewnątrz (nawis dachowy)?

odpowiedz | To było pomocne (5) (Przetłumaczone przez Google)
Van der Bij 11-08-2021
Nie rozmawiaj z nim

odpowiedz | To było pomocne (0) (Przetłumaczone przez Google)

Więcej o tej instrukcji

Rozumiemy, że miło jest mieć papierową instrukcję obsługi Steinel IS 140-2 Czujnik ruchu. Zawsze możesz pobrać instrukcję z naszej strony internetowej i wydrukować ją samodzielnie. Jeśli chcesz otrzymać oryginalną instrukcję, zalecamy skontaktowanie się z Steinel. Być może będą w stanie dostarczyć oryginalną instrukcję. Szukasz instrukcji swojego Steinel IS 140-2 Czujnik ruchu w innym języku? Wybierz preferowany język na naszej stronie głównej i wyszukaj numer modelu, aby sprawdzić, czy jest on dostępny.

Dane techniczne

Marka Steinel
Model IS 140-2
Kategoria Czujniki ruchu
Typ pliku PDF
Rozmiar pliku 18.03 MB

Wszystkie podręczniki dla Steinel Czujniki ruchu
Więcej podręczników Czujniki ruchu

Instrukcja Steinel IS 140-2 Czujnik ruchu

Produkty powiązane

Powiązane kategorie