Instrukcja Nedis HCBL400WT Ciśnieniomierz

Potrzebujesz instrukcji dla swojego Nedis HCBL400WT Ciśnieniomierz? Poniżej możesz bezpłatnie obejrzeć i pobrać instrukcję w formacie PDF w języku polskim. Ten produkt ma obecnie zadane 2 pytania, 0 komentarzy i 0 głosów. Jeśli nie jest to podręcznik, którego szukasz, skontaktuj się z nami.

Czy Twój produkt nie działa, a w instrukcji obsługi brakuje rozwiązania Twojego problemu? Udaj się do Repair Café, gdzie naprawisz swój sprzęt za darmo.

Instrukcja

Loading…

a
Quick start guide
Blood Pressure Monitor
HCBL400WT
For more information see the extended manual online: ned.is/hcbl400wt
Intended use
This product is intended to measure the diastolic and systolic blood pressure and pulse rate
of an adult.
The product is not intended for use on neonates, children or pregnant women.
This product is not intended for medical use.
The product is intended for indoor use only.
Any modication of the product may have consequences for safety, warranty and proper
functioning.
Specications
Product Blood Pressure Monitor
Article number HCBL400WT
Dimensions (l x w x h) 136 x 120 x 61 mm
Weight (excl. batteries and cu) 225g
Cu circumference 22 - 42 cm
Measuring method Oscillometric method, automatic ination and measurement
Measurement range
Cu pressure 0 - 300 mmHg
Systolic 60 - 260 mmHg
Diastolic 40 - 199 mmHg
Pulse rate 40 - 180 beats/minute
Accuracy
Pressure ± 3 mmHg
Pulse rate Less than 60: ±3bpm
More than 60 (incl.) : ±5%
Precision 1 mmHg
Memory 2 x 60 measurements
Battery type 4 x 1.5 V AA batteries (not included)
Battery life Approximately 270 times
Operating temperature 10 - 40 °C
Storage temperature -20 - 50 °C
Relative humidity ≤85 %
Environmental pressure 80 - 105 kPa
Main parts (image A)
1 Storage bag
2 Cu
3 Rubber air tube
4 Air tube connector
5 Battery compartment
6 Memory button
7 Start button
8 Irregular heartbeat indicator
9 Low battery indicator
q Pressure in the cu is instable or there is a lot of
remnant air in the cu
w Blood pressure level classication indicator
e Time and date display
r Systolic blood pressure
t Diastolic blood pressure
y Pulse rate
Safety instructions
-
WARNING
Ensure you have fully read and understood the instructions in this document before you
install or use the product. Keep the packaging and this document for future reference.
Only use the product as described in this document.
Do not use the product if a part is damaged or defective. Replace a damaged or defective
product immediately.
Do not drop the product and avoid bumping.
Do not expose the product to water or moisture.
Only use the provided power cable.
Disconnect the product from the power source and other equipment if problems occur.
Do not unplug the product by pulling on the cable. Always grasp the plug and pull.
This product may only be serviced by a qualied technician for maintenance to reduce the
risk of electric shock.
Consult with a doctor before use if you have any medical concerns.
Do not use this product in a moving vehicle. This may result in inaccurate measurements.
Inserting the batteries (image B)
1. Open the battery compartment A
5
.
2. Place the batteries.
3. Close A
5
.
Setting the time and date
1. Press and hold the start button A
7
and the memory button A
6
simultaneously for two
seconds.
The time format starts to blink. The product is now in time format adjustment mode.
4
If no button is pressed for 60 seconds, the product exits time and date adjustment mode.
2. Press A
6
to change the time format.
3. Press A
7
to conrm.
The product is now in year adjustment mode.
4. Press A
6
to adjust the number.
5. Press A
7
to conrm.
The product is now in month adjustment mode.
6. Repeat steps 4 – 5 to set the month, date, hour and minutes.
Connecting the cu
1. Insert the rubber air tube A
3
into the air tube connector A
4
.
4
The connector must be completely inserted to prevent air leakage during blood pressure
measurements.
Applying the cu
1. Place the cu A
2
around a bare upper arm.
4
A
2
must be placed 1-2 cm above the elbow joint.
2. Choose an arm to measure on. Always measure on the same arm.
4
If A
2
is applied on the left arm, A
3
must be on the inside of the arm, aligned with the
middle nger.
4
If A
2
is applied on the right arm, A
3
must be at the side of the elbow.
4
A
2
should be tight but comfortable. It should be possible to insert a nger between the
arm and A
2
.
Body posture during measurement
Sitting down
1. Sit down.
2. Put your feet at on the oor.
3. Place your hand on a at surface with the palm up.
4
Do not rest your arm on A
3
. This may restrict the airow to A
2
.
4. Position your arm so A
2
is at the same height as your heart.
5. Sit calmly for 5 minutes before starting the blood pressure measurement.
Lying down
1. Lie on your back.
2. Place your arm straight along your side with the palm up.
3. Position your arm so A
2
is at the same height as your heart.
4. Lie calmly for 5 minutes before starting the blood pressure measurement.
Measuring blood pressure
1. Press A
7
.
4
All symbols - A
8
to A
y
- are shown on the display. If not all symbols are visible, contact
the service center.
The current memory group starts to blink in the place of A
t
.
4
Memory groups can be used to store measurements for multiple people on the same
device.
2. Press A
6
to switch memory groups.
3. Press A
7
to conrm.
4
The memory group is also conrmed automatically after 5 seconds of inactivity.
The display shows the most recent measurements.
If no measurements are stored in the memory group, the display shows zeroes.
The product starts to seek zero pressure.
A
2
inates until sucient pressure has built up for a measurement.
A
2
slowly deates while the measurement is carried out.
The results are shown on the display.
4
The measurements are automatically stored.
4. Press A
7
to switch o the display manually.
4
The display switches o automatically after 1 minute of inactivity.
Reading measurements from the memory
1. Press A
6
.
The current memory group is shown in the place of A
t
.
2. Press A
7
to switch memory groups.
3. Press A
6
to conrm.
4
The memory group is also conrmed automatically after 5 seconds of inactivity.
The display shows the average values of all measurements in the current memory group.
If no measurements are stored in the memory group, the display shows zeroes.
4. Press A
6
to show the average values of the last three measurements in the current
memory group.
5. Press A
6
to show the number of stored measurements in the current memory group.
6. Press A
6
to show the most recent measurements.
7. Press A
6
repeatedly to show the previous measurements.
8. Press A
7
to switch o the display manually.
4
The display switches o automatically after 1 minute of inactivity.
Deleting measurements from the memory
1. When the display shows a measurement, press and hold A
6
for three seconds to delete
all measurements in the current memory bank.
Technical alarm
If the measured blood pressure is outside the rated range, the display shows ‘Hi’ or ‘Lo’ as
technical alarm.
1. Check if the measurement was performed correctly.
2. If the measurement was performed correctly, consult your physician.
Pobierz instrukcję w języku polskim (PDF, 0.95 MB)
(Apelujemy o dbanie o środowisko i drukowanie instrukcji tylko wtedy, gdy jest to niezbędne)

Loading…

Ocena

Podziel się z nami swoją opinią na temat Nedis HCBL400WT Ciśnieniomierz i oceń urządzenie. Chcesz podzielić się swoimi doświadczeniami z tym produktem lub zadać pytanie? Zostaw komentarz na dole strony.
Czy jesteś zadowolony z Nedis HCBL400WT Ciśnieniomierz?
Tak Nie
Zostań pierwszą osobą, która oceni ten produkt
0 głosów

Dołącz do dyskusji na temat tego produktu

Tutaj możesz podzielić się swoją opinią na temat Nedis HCBL400WT Ciśnieniomierz. Jeśli masz pytanie, najpierw dokładnie przeczytaj instrukcję. Zapytanie o instrukcję można złożyć za pomocą naszego formularza kontaktowego.

Więcej o tej instrukcji

Rozumiemy, że miło jest mieć papierową instrukcję obsługi Nedis HCBL400WT Ciśnieniomierz. Zawsze możesz pobrać instrukcję z naszej strony internetowej i wydrukować ją samodzielnie. Jeśli chcesz otrzymać oryginalną instrukcję, zalecamy skontaktowanie się z Nedis. Być może będą w stanie dostarczyć oryginalną instrukcję. Szukasz instrukcji swojego Nedis HCBL400WT Ciśnieniomierz w innym języku? Wybierz preferowany język na naszej stronie głównej i wyszukaj numer modelu, aby sprawdzić, czy jest on dostępny.

Dane techniczne

Marka Nedis
Model HCBL400WT
Kategoria Ciśnieniomierze
Typ pliku PDF
Rozmiar pliku 0.95 MB

Wszystkie podręczniki dla Nedis Ciśnieniomierze
Więcej podręczników Ciśnieniomierze

Często zadawane pytania dotyczące Nedis HCBL400WT Ciśnieniomierz

Nasz zespół wyszukuje przydatne informacje na temat produktu i udziela odpowiedzi na często zadawane pytania. Jeśli znajdziesz nieścisłości lub błędy w naszych odpowiedziach na pytania, poinformuj nas o tym przy pomocy naszego formularza kontaktowego.

Zmierzyłem ciśnienie krwi za pomocą aparatu do mierzenia ciśnienia krwi, ale co to jest uznawane za "normalne" ciśnienie krwi? Zweryfikowany

Ogólnie ciśnienie skurczowe wynoszące 120 i ciśnienie rozkurczowe 80 jest uważane za prawidłowe lub zdrowe. Osoby w wieku 60 lat i starsze mogą mieć nieco wyższe ciśnienie krwi.

To było pomocne (1222) Czytaj więcej

Co to jest skurczowe i rozkurczowe ciśnienie krwi? Zweryfikowany

Podczas pomiaru ciśnienia krwi wyświetlane są dwie wartości, ciśnienie skurczowe i rozkurczowe. Ciśnienie skurczowe to ciśnienie w żyłach, kiedy serce kurczy się, a ciśnienie rozkurczowe to ciśnienie w żyłach, wtedy serce się rozluźnia.

To było pomocne (472) Czytaj więcej
Instrukcja Nedis HCBL400WT Ciśnieniomierz